Utilization of Labview in MIMO Control for Multiple Tanks Level Measurement System
Kalaiselvi B1, Vijayan T2, Sridharraja D3, Abinethri R4
1B.Kalaiselvi, Department of EIE, Bharath Institute of Higher Education and Research, (Tamil Nadu), India.
2Sridhar Raja D, Department of EIE, Bharath Institute of Higher Education and Research, (Tamil Nadu), India.
3T.Vijayan, Department of EIE, Bharath Institute of Higher Education and Research, (Tamil Nadu), India.
4R.Abinethri, Department of EIE, Bharath Institute of Higher Education and Research, (Tamil Nadu), India.
Manuscript received on 14 September 2019 | Revised Manuscript received on 23 September 2019 | Manuscript Published on 10 October 2019 | PP: 436-438 | Volume-8 Issue-6S2, August 2019 | Retrieval Number: F11230886S219/19©BEIESP | DOI: 10.35940/ijeat.F1123.0886S219
Open Access | Editorial and Publishing Policies | Cite | Mendeley | Indexing and Abstracting
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC-BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
Abstract: The modernisation of the existing device of facts acquisition machine in procedure manage is upgraded to the recent technologies for running the technique station. This paper offers the perspectives on the prevailing 3 tank structures installation is used for controlling the levels of two interacting systems. Liquid degree control has a completely big software domain in enterprise circulate over; the 3 tank system is one of the most broadly used experiments in laboratory & studies institutes. The measurement of business technique level parameter is one of the wonderful importances in manner manage. the extent of liquids may additionally have an effect on each the stress and fee of float in and out of the tank. subsequently, the excellent can be affected. automated manage applications would require control indicators for operation of actuation. stage transmitter is used to measure level of the tank. in this gadget the level in the process tank is sensed the usage of a degree transmitter and the corresponding present day output being measured and managed with the aid of the use of statistics acquisition gadget. [1],[ 3],[5].
Keywords: Closed Loop, Cascade Control, LabView, Virtual Instrumentation.
Scope of the Article: Measurement & Performance Analysis