Abstract: This manuscript covers the analytical and optimization based techniques for the performance assessment of 3-phase IAG furnishing 3-phase and 1-phase load. It examines initially the basic phenomenon of voltage build-up and then the steady state performance of 3-phase IAG furnishing 3-phase and 1-phase load. This preliminary study forms the foundation or basis of the design of future controllers. The conventional techniques and MATLAB based optimization technique fsolve is elaborated in detail along-with advantages and disadvantages for attaining the solution of simultaneous non linear equation. The fsolve technique is recommended for the solution of non-linear equations due to its advantages over conventional method.
Keywords: IAG, steady-state condition, transient state condition, Numerical techniques, MATLAB, fsolve technique, Optimisation.