Loading

Experimental Study of Heat Transfer Rate in Single and Series Cross Flow Heat Exchanger using Matlab Coding
P.Parabrahma Sai1, K.Lakshmi Prasad2, P.Ravindra Kumar3, K. Srinivasa Rao4

1P. Parabrahma Sai*, Mechanical engineering, Lakireddy Bali reddy college of engineering, Mylavaram.
2K. Lakshmi Prasad, Mechanical engineering, Lakireddy Bali reddy college of engineering, Mylavaram.
3P. Ravindra Kumar, Mechanical engineering, Lakireddy Bali reddy college of engineering, Mylavaram.
4K. Srinivasa Rao, Mechanical engineering, Lakireddy Bali reddy college of engineering, Mylavaram.
Manuscript received on October 05, 2020. | Revised Manuscript received on October 10, 2020. | Manuscript published on October 30, 2020. | PP: 273-280 | Volume-10 Issue-1, October 2020. | Retrieval Number: 100.1/ijeat.A18361010120 | DOI: 10.35940/ijeat.A1836.1010120
Open Access | Ethics and Policies | Cite | Mendeley
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

Abstract: The present study investigates the heat transfer rate and effectiveness of cross flow heat exchanger by varying velocity and mass flow rate of the cold and hot fluids.The velocity of the cold fluid i.e. air varying from 15m/s to 30m/s(with an intermediate step of 20m/s and 25m/s) whereas the mass flow rate of hot fluid i.e. water is taken as 35lit/hr and 84lit/hr. The logarithmic mean temperature difference (LMTD) method is used to find the heat transfer rate. In thepresent workthe effectiveness and heat transfer rate werecompared between the single and series cross flow heat exchangers. The result shows an average increase of 47.14% and 59.59% of heat transfer rate analogous to mass flow rate of 84lit/hrand 35lit/hr. 
Keywords: Cross flow Heat exchanger, Effectiveness, Heat transfer rate, Logarithmic mean temperature difference.