Performance Assessment Techniques for the 3-Phase IAG
Shakuntla Boora
Dr. Shakuntla Boora*, Electrical Engg. Department, JCBUST, YMCA, Faridabad, Haryana.
Manuscript received on November 22, 2019. | Revised Manuscript received on December 15, 2019. | Manuscript published on December 30, 2019. | PP: 2191-2200 | Volume-9 Issue-2, December, 2019. | Retrieval Number: B3729129219/2019©BEIESP | DOI: 10.35940/ijeat.B3729.129219
Open Access | Ethics and Policies | Cite | Mendeley
© The Authors. Blue Eyes Intelligence Engineering and Sciences Publication (BEIESP). This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)
Abstract: This manuscript covers the analytical and optimization based techniques for the performance assessment of 3-phase IAG furnishing 3-phase and 1-phase load. It examines initially the basic phenomenon of voltage build-up and then the steady state performance of 3-phase IAG furnishing 3-phase and 1-phase load. This preliminary study forms the foundation or basis of the design of future controllers. The conventional techniques and MATLAB based optimization technique fsolve is elaborated in detail along-with advantages and disadvantages for attaining the solution of simultaneous non linear equation. The fsolve technique is recommended for the solution of non-linear equations due to its advantages over conventional method.
Keywords: IAG, steady-state condition, transient state condition, Numerical techniques, MATLAB, fsolve technique, Optimisation.